Marine Isolation transformers are used on-board vessels or dock-side as part of marina power distribution systems. Our marine isolation transformers are available in five standard designs and either light gray powder coated or stainless steel enclosures. Stainless Steel Enclosure Light Gray Powder Coated Enclosure
The isolation transformers totally isolate the earth-bonded shore AC power from on-board electrical systems and
greatly reduce the risk of shock caused by defective
electrical systems, and largely eliminate corrosion of
metal parts caused by stray AC current.
Problems with the AC supply may be caused by insulation breakdown, immersed wiring, incorrect wiring or equipment failure. If the 3rd (green) ground wire is connected to the onboard bonding circuit, corrosion, excessive erosion of zinc electrodes and shock due to stray current may result.
In addition corroded wiring in the shore installation may send considerable voltages down the ground wire without tripping
the AC circuit breaker causing damage to onboard electronics.


Voltages (VAC) Frequency VA rating Enclosure Dimensions Weight
Input Output Hz VA mm inch lbs Kg
120 120 60 2,400 250x300x150 10x12x6 38 17.2
120/240 120 50/60 3,600 300x400x150 12x16x6 50 22.7
240/120 240 50/60 6,000 300x400x150 12x16x6 75 34.0
240/120 240 50/60 9,000 400x500x150 16x20x6 100 45.3
240/120 240 50/60 12,000 400x500x 200 16x20x8 150 68.0
Advantages of Toroidal Isolation Transformers
| The advantages of a toroidal transformer allow the stainless steel enclosure to be much smaller than when a conventional stacked lamination type transformer is used. Smaller dimensions also mean much lower total weight of the enclosed isolation transformer. |
Both features are certainly of paramount importance onboard vessels of any size. Click here to read more about the unique features of toroidal isolation and power transformers. |
Isolation Transformer Safety Standard Certifications
UL 60601.1, CSA C22.2 No 601.1-M90 (1990), EN61558-1, IEC60601-1, CE Marking
Medical Safety Standard with maximum leakage current of 100 to 300 microamperes depending on the power rating of the transformer.
Enclosure Specifications
NEMA 4X style, 14 gauge stainless steel, water tight enclosures with hinged and lockable door. Input and output wires are terminated through sealed stress relief cable glands at the bottom of enclosures to a terminal block inside the enclosure.
Please email us for pricing and availability: sales@bridgeportmagnetics.com